Flat entrance fire doors: who is responsible?

Short answer: Ownership of a flat entrance door depends on the lease, but the Fire Safety Act 2021 confirmed that flat entrance doors in multi-occupied residential buildings fall within the Fire Safety Order, so the responsible person must account for them in the fire risk assessment. In England, regulation 10 adds annual best-endeavours checks above 11 metres.

  • Ownership depends on the lease
  • Fire Safety Act 2021 brings doors in scope
  • Annual checks above 11 m (England)
  • Non-rated replacements are common
Grey flat entrance fire door with a spyhole and lever handle in an apartment corridor

Who owns a flat entrance door?

It depends on the lease. Some leases demise the door to the leaseholder, others keep it with the freeholder, and some split the door and frame. Check the lease plan and definitions.

Who is responsible for its fire safety?

Since the Fire Safety Act 2021, the Fire Safety Order clearly applies to flat entrance doors in multi-occupied residential buildings in England and Wales. The responsible person must consider them in the fire risk assessment and take reasonable steps where they are not adequate, even if the leaseholder owns the door.

What extra checks apply in England?

In residential buildings with storeys over 11 metres, regulation 10 requires the responsible person to use best endeavours to check flat entrance doors, including their self-closers, every year, and to keep evidence where access is refused.

What are the most common problems?

  • Leaseholders replacing the door with a non-fire-rated one
  • Self-closers removed or disconnected
  • Non-fire-rated letter plates, spy holes or cat flaps
  • Extra locks or chains drilled through the leaf
  • Gaps opened by new flooring and planing

What happens if a leaseholder's door is non-compliant?

The responsible person should record it, inform the leaseholder and agree a remedy, which may be repair or replacement. The lease and any building safety obligations will shape who pays. Clear photo evidence from the check helps those conversations.

Related services

Related questions

Who is responsible for a flat entrance fire door?

It depends on the lease, but since the Fire Safety Act 2021 the Fire Safety Order clearly covers flat entrance doors in multi-occupied residential buildings, so the responsible person must account for them in the fire risk assessment even where the leaseholder owns the door.

What does best endeavours mean?

The government fact sheet describes it as the responsible person deciding how to engage residents to gain access and keeping evidence, such as correspondence, where access is refused or not possible.

When should a fire door be replaced rather than repaired?

When the leaf or frame is too damaged to repair within what its test evidence allows, when there is no evidence it is a fire door, or when the repair would cost more than a new doorset.

How long does a replacement take?

Most single doorsets are replaced within a day, including making good. Doors are never left unable to close at the end of a working day.

Sources checked 9 October 2026: GOV.UK Fire Safety (England) Regulations 2022 fact sheets; BSI and FPA announcements on BS 8214:2026; FDIS published inspection data. This guide is general information, not legal advice.

Add Fire Door Inspections as a preferred source on Google

Book your fire door inspection

Tell us about your building and get a fixed price, with every remedial item priced separately.