Fire door glossary
56 fire door terms, explained in plain English.
- Fire door
- A door designed, tested and installed to resist the passage of fire for a set time when closed, as part of a building's fire strategy.
- Fire doorset
- A complete fire door assembly supplied as one unit: leaf, frame, seals and hardware, tested together.
- Door leaf
- The opening part of a door, as distinct from the frame.
- FD30
- A fire door designed to resist fire for 30 minutes in a standard fire test.
- FD60
- A fire door designed to resist fire for 60 minutes in a standard fire test.
- FD30S / FD60S
- A fire door that also restricts the passage of cold smoke, usually with smoke seals and a controlled threshold gap.
- Intumescent strip
- A strip in the edge of a door or frame that expands in heat to seal the gap around the leaf during a fire.
- Smoke seal
- A brush, fin or blade seal that blocks cold smoke before an intumescent strip reacts.
- Self-closing device
- A closer that returns a fire door to the fully closed and latched position after it has been opened.
- Overhead closer
- A surface-mounted closer fixed to the head of the door or frame with an arm.
- Concealed closer
- A closer housed within the door leaf or frame, which needs specific fire test evidence for the door type.
- Free-swing closer
- A closer that lets a door move freely in normal use and closes it when the fire alarm activates.
- Hold-open device
- A device that holds a fire door open and releases it on fire alarm activation.
- Door gap
- The clearance between the door leaf and its frame, or between the leaf and the floor.
- Threshold gap
- The gap under a door leaf, also called the undercut.
- Meeting stiles
- The two vertical edges where the leaves of a pair of doors meet.
- Lipping
- A strip of hardwood fixed to the edge of a door leaf, sometimes used to correct gaps where the door's evidence allows.
- Rebate
- The recess in a door frame that the leaf closes against.
- Door stop
- The part of the frame the leaf closes against, forming the rebate.
- Vision panel
- A glazed opening in a door leaf so people can see through it.
- Glazing bead
- The strip that holds glass in place in a door; fire doors need fire-rated beads and fixings.
- Integrity
- A fire door's ability to stop flames and hot gases passing through.
- Insulation
- A fire door or glazing system's ability to limit heat transfer to the unexposed side.
- Air transfer grille
- A ventilation grille in a door or wall; in fire doors it must close in a fire, usually with intumescent material.
- Certification label
- A label or plug, often on the top or hinge edge, showing the door was made under a third-party certification scheme.
- Test evidence
- The fire test reports and assessments that show how a door construction performed and what it can be used with.
- Field of application
- The range of sizes, hardware and variations a door's test evidence covers.
- Responsible person
- The person or organisation with legal duties for fire safety in a building, typically the employer, owner or person in control of the premises; managing agents often act on their behalf.
- Fire risk assessment
- A documented assessment of fire risks in a building and the measures needed, including fire doors.
- Regulation 10
- The part of the Fire Safety (England) Regulations 2022 requiring quarterly communal fire door checks and annual flat entrance door checks in residential buildings with storeys over 11 metres.
- Fire Safety Order
- The Regulatory Reform (Fire Safety) Order 2005, the main fire safety law for non-domestic premises and common parts in England and Wales.
- Fire Safety Act 2021
- An Act that clarified the Fire Safety Order applies to the structure, external walls and flat entrance doors of multi-occupied residential buildings.
- Building Safety Act 2022
- The Act that created the new building safety regime and strengthened duties under the Fire Safety Order.
- BS 8214
- The British Standard code of practice for fire-resisting and smoke control doors; the current edition is BS 8214:2026.
- BS EN 1634-1
- The European fire resistance test standard for doors and shutters.
- BS 476-22
- The older British fire resistance test for non-loadbearing elements, still referenced for many existing doors.
- BS EN 13501-2
- The classification standard for fire resistance, using classes such as E30 and EI 30.
- BS EN 1154
- The standard for controlled door closing devices.
- BS EN 1155
- The standard for electrically powered hold-open devices for swing doors.
- BS EN 1935
- The standard for single-axis hinges, used to specify hinges suitable for fire doors.
- BS EN 1125
- The standard for panic exit devices operated by a horizontal bar.
- BS EN 179
- The standard for emergency exit devices operated by a lever handle or push pad.
- Fire stopping
- Sealing gaps and openings in fire-resisting walls and floors, including the gap between a door frame and the wall.
- Compartmentation
- Dividing a building into fire-resisting compartments so fire and smoke are contained.
- Progressive horizontal evacuation
- Moving people behind fire doors into an adjacent compartment, common in hospitals and care homes.
- Protected route
- An escape route enclosed by fire-resisting construction, such as a protected stair.
- Final exit
- The point where an escape route leaves the building to a place of safety.
- Cross-corridor door
- A fire door across a corridor that divides it into sections to limit smoke spread.
- Flat entrance door
- The front door of a flat opening onto a common corridor or stair, usually required to be a fire door.
- Common parts
- Corridors, stairs, lobbies and other areas shared by residents of a building.
- Best endeavours
- Under regulation 10, taking reasonable steps to gain access to check flat entrance doors and keeping evidence where access is not possible.
- Remedial works
- Repairs carried out to put right defects found in an inspection or fire risk assessment.
- Door register
- A record of every fire door in a building with its reference, location, specification and history.
- Defect grading
- Ranking defects by urgency, from immediate risk to planned maintenance.
- Kick plate
- A protective plate on the lower face of a door; on fire doors its size and fixing must be within the door's evidence.
- Letter plate
- A letter box in a door; on flat entrance fire doors it must be fire-rated.
Questions we're asked
What do FD30 and FD60 mean?
FD30 and FD60 describe fire doors designed to resist fire for 30 or 60 minutes in a standard test. An S suffix, such as FD30S, means the door also restricts the passage of cold smoke.
What gap is acceptable around a fire door?
Typically 2 to 4 mm at the head and edges, with 3 mm as a practical target, unless the door's certification gives a different figure. Under-door gaps depend on the door; smoke control doors usually need 3 mm or less or a tested drop seal.