FIREDOORINSPECTIONS.UK

Wales

Intumescent & Smoke Seal Replacement in Dyfed

Across Dyfed, including rural and island locations, we carry out fire door seal replacements for landlords, housing providers, schools and businesses.

Intumescent & Smoke Seal Replacement: Intumescent seals are strips set into the edge of a fire door or its frame that expand when heated to close the gap around the door. Smoke seals, usually brush or fin seals, block cold smoke before the intumescent reacts. Both are part of the door's tested performance.

Area
Dyfed
Region
Wales
Postcode areas
SA, SY
Towns listed
2
Local authorities
Carmarthenshire, Ceredigion, Pembrokeshire
Fire safety law
Wales: Fire Safety Order 2005

What's included in Dyfed?

  • Threshold or drop-down seals where smoke control is required
  • Intumescent-only or combined intumescent and smoke seals as required
  • Gap readings checked so new seals can work
  • Seals on hanging, closing and head edges, and meeting stiles on pairs
  • Old seals removed cleanly from the groove
  • Survey of the seal type, size and position for each door

How does it work in Dyfed?

  1. Identify

    We confirm the seal type and size the door needs.

  2. Remove

    Old or damaged seals are removed and grooves cleaned.

  3. Fit

    New seals are fitted in continuous lengths, mitred at the head.

  4. Check

    The door is closed and checked for binding or gaps.

Which fire door rules apply in Dyfed?

Dyfed is in Wales, where the Fire Safety Order 2005 requires fire doors to be maintained. Regulation 10's fixed quarterly and annual schedule is English law, but many Welsh landlords follow it as good practice.

  • Fire Safety Order 2005 applies in Wales
  • Fire Safety Act 2021: flat entrance doors are within scope
  • Regulation 10's fixed schedule is England-only
  • Quarterly and annual checks still widely used as good practice

Guide prices in Dyfed

Typical Dyfed prices: £45–£110 per door (ex VAT). Minimum visit from £145.

Intumescent & Smoke Seal Replacement by town in Dyfed

Intumescent & Smoke Seal Replacement in Dyfed: questions

Can I just stick new seals over the old ones?

No. Seals should be fitted into the groove after the old seal is removed, in the size and type the door was tested with.

Can intumescent strips be painted?

Brush and fin smoke seals should never be painted, because paint stops them working. Some intumescent strips tolerate a light coat, but the safest rule is to mask all seals before decorating and replace any that have been painted.

Does regulation 10 apply in Dyfed?

No. Dyfed is in Wales and regulation 10 is English law. The Fire Safety Order 2005 still requires fire doors to be maintained, and many Welsh landlords follow the same quarterly and annual routine as good practice.

Do you cover the area around Dyfed?

Yes. As well as Dyfed itself we cover nearby towns including Llanelli, Ammanford and nearby towns.

Other services in Dyfed

Intumescent & Smoke Seal Replacement in Dyfed

Missing, damaged or painted seals replaced with strips that suit the door's rating and gaps.