In short: annual flat entrance door checks are the yearly checks of each flat's front door, and its self-closer, that regulation 10 requires on a best-endeavours basis in English residential buildings with storeys over 11 metres.
- Town
- Chelsea
- County / area
- Greater London
- Postcode district
- SW3
- Region
- London
- Fire safety law
- England: Fire Safety Order 2005 + regulation 10 above 11 m
- Nearest town
- Battersea (2 km)
Fire doors in Chelsea's buildings
Buildings in Chelsea range from post-war council blocks to new-build towers and converted Victorian houses split into flats, each with its own fire door issues. Reports for Chelsea buildings keep the same door references from one visit to the next.
What happens on site in Chelsea?
- A written record of every attempt where access is refused or not possible
- A per-flat result that can be shared with the leaseholder
- Flags for doors replaced by residents without fire rating evidence
- Resident notification letters and booking slots
- Repeat visits for missed appointments
| Seals | Intumescent and smoke seals present and continuous around the leaf. |
|---|---|
| Alterations | No unauthorised replacement, cat flaps, extra locks or cut-down leaves. |
| Closer | A self-closing device is fitted and closes the door fully against the frame. |
Full details on our annual flat entrance door checks page.
Why Chelsea clients choose us
Priced door by door
Every failed item in Chelsea is priced separately, so you approve exactly what you want done.
Same report everywhere
Whether your building is in Chelsea or across the country, the report format, defect grading and pricing are the same.
Photos of every defect
You get photographs of every defect found in Chelsea, linked to a door reference you can find again.
Fire door law for Chelsea buildings
Buildings in Chelsea fall under English fire safety law: the Fire Safety Order 2005 requires fire doors to be maintained, and in multi-occupied residential buildings over 11 metres regulation 10 sets quarterly and annual checks.
Prices in Chelsea
Guide prices for flat entrance door checks in Chelsea are typically £15–£28 per flat, ex VAT. Get a guide price for your Chelsea building.
Questions from Chelsea clients
Does regulation 10 apply to buildings in Chelsea?
Yes, if the building is a multi-occupied residential building with storeys over 11 metres. Chelsea is in England, so the quarterly communal door checks and annual flat entrance door checks apply to those buildings.
Do you cover the area around Chelsea?
Yes. As well as Chelsea itself we cover nearby towns including Battersea, Fulham and Pimlico.
What does best endeavours mean?
The government fact sheet describes it as the responsible person deciding how to engage residents to gain access and keeping evidence, such as correspondence, where access is refused or not possible.
Who is responsible for a flat entrance fire door?
It depends on the lease, but since the Fire Safety Act 2021 the Fire Safety Order clearly covers flat entrance doors in multi-occupied residential buildings, so the responsible person must account for them in the fire risk assessment even where the leaseholder owns the door.
Also covering towns near Chelsea
- Annual Flat Entrance Door Checks in Battersea
- Annual Flat Entrance Door Checks in Fulham
- Annual Flat Entrance Door Checks in Pimlico
- Annual Flat Entrance Door Checks in City of Westminster
- Annual Flat Entrance Door Checks in Notting Hill
- Annual Flat Entrance Door Checks in London
Other fire door services in Chelsea
- Fire Door Signage in Chelsea
- Fire Door Maintenance Contracts in Chelsea
- Fire Exit Door Checks in Chelsea
- Fire Door Tagging & Asset Registers in Chelsea
- Fire Door Repairs in Chelsea
- Fire Door Gap Adjustment in Chelsea
- Fire Stopping Around Doors in Chelsea
- Fire Door Inspections in Chelsea
- All services in Chelsea