Northern Ireland
Fire Stopping Around Doors in County Fermanagh
We provide fire stopping works across County Fermanagh, with the same report format and pricing as everywhere else we work.
Fire Stopping Around Doors: Fire stopping is the sealing of gaps and openings in fire-resisting walls and floors so fire and smoke cannot pass through. Around a fire door it mainly means the gap between the door frame and the wall, which must be sealed as well as the door itself.
- Area
- County Fermanagh
- Region
- Northern Ireland
- Postcode areas
- BT
- Towns listed
- Whole area covered
- Local authorities
- County Fermanagh
- Fire safety law
- NI: Fire and Rescue Services (NI) Order 2006
Included as standard across County Fermanagh
- Architraves refitted after sealing
- Photographs before and after each seal
- Frame-to-wall gaps exposed and inspected
- Service penetrations near doors sealed in compartment walls
- Penetration labels and a register where required
- Gaps sealed with suitable intumescent mastic, foam or stone wool
How does it work in County Fermanagh?
Expose
Architraves are removed where needed to see the frame gap.
Select
The sealing method is chosen to suit the gap and wall.
Seal
Gaps and penetrations are sealed and photographed.
Record
Each location is logged with photos for the building file.
Which fire door rules apply in County Fermanagh?
Northern Irish law applies in County Fermanagh: the Fire and Rescue Services (NI) Order 2006 and 2010 regulations. Regulation 10 is English law, but regular documented checks support your fire risk assessment.
- Fire and Rescue Services (NI) Order 2006
- Fire Safety Regulations (Northern Ireland) 2010
- Regulation 10's fixed schedule is England-only
- Regular documented checks support the fire risk assessment
Prices across County Fermanagh
In County Fermanagh, fire stopping works typically cost £60–£180 per door frame ex VAT, depending on the building and specification.
Coverage in County Fermanagh
We cover every part of County Fermanagh, including the postcode districts BT74, BT92, BT93, BT94. Visits are grouped by district to keep travel costs down.
Fire Stopping Around Doors in County Fermanagh: questions
Is expanding foam acceptable around a fire door frame?
Only a fire-rated foam with evidence for that use and gap size. Ordinary expanding foam is not suitable. BS 8214:2026 lists acceptable approaches such as suitable mastics, foams and stone wool.
Will I get photos?
Yes. Every sealed location is photographed before and after, and logged.
Which fire safety law applies in County Fermanagh?
The Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 require fire safety measures, including fire doors, to be maintained.
How quickly can you inspect fire doors in County Fermanagh?
It depends on the number of doors and access. Tell us what you need and we will give you the earliest date when you call, and confirm it in writing.