FIREDOORINSPECTIONS.UK

Northern Ireland

Fire Door Gap Adjustment in County Londonderry

Across County Londonderry, from Londonderry County Borough to smaller towns and villages, we carry out fire door gap adjustments for landlords, housing providers, schools and businesses.

Fire Door Gap Adjustment: Fire door gap adjustment is the work needed to bring the gaps between a fire door leaf and its frame, and under the door, back within the tolerance in the door's evidence, typically 2 to 4 mm around the edges.

Area
County Londonderry
Region
Northern Ireland
Postcode areas
BT
Towns listed
3
Local authorities
Coleraine, Derry, Limavady, Magherafelt
Fire safety law
NI: Fire and Rescue Services (NI) Order 2006

What every job in County Londonderry includes

  • Frame adjustment or re-fixing where the frame has moved
  • Hinges re-packed or replaced where the leaf has dropped
  • Hardwood lippings fitted to narrow leaves where the evidence allows
  • Gap readings at head, hinge side, closing side and threshold
  • Threshold gaps corrected or drop seals fitted on smoke control doors
  • Final readings recorded for the door's file

How does it work in County Londonderry?

  1. Measure

    Gaps are measured at several points on every edge.

  2. Diagnose

    We identify why the gap has opened.

  3. Correct

    Hinges, leaf or frame are corrected using a method the door's evidence supports.

  4. Re-measure

    Final gap readings are recorded.

Northern Ireland fire safety law across County Londonderry

For buildings in County Londonderry, the Fire Safety Regulations (Northern Ireland) 2010 set the maintenance duty; the English regulation 10 schedule does not apply.

  • Fire and Rescue Services (NI) Order 2006
  • Fire Safety Regulations (Northern Ireland) 2010
  • Regulation 10's fixed schedule is England-only
  • Regular documented checks support the fire risk assessment

Prices across County Londonderry

In County Londonderry, fire door gap adjustments typically cost £90–£260 per door ex VAT, with visits from £145.

Fire Door Gap Adjustment by town in County Londonderry

Fire Door Gap Adjustment in County Londonderry: questions

Why do gaps open up over time?

Hinges wear and drop, frames shrink or move, leaves warp, and doors are sometimes planed after flooring changes. Each needs a different repair.

How big can the gap under a fire door be?

It depends on the door's evidence. Doors without smoke control often allow a larger threshold gap, sometimes up to around 8 to 10 mm, while smoke control doors usually need 3 mm or less or a tested drop seal.

Does regulation 10 apply in County Londonderry?

No. County Londonderry is in Northern Ireland, where the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 apply.

How quickly can you inspect fire doors in County Londonderry?

It depends on the number of doors and access. Tell us what you need and we will give you the earliest date when you call, and confirm it in writing.

Other services in County Londonderry

Fire Door Gap Adjustment in County Londonderry

Excessive or uneven gaps corrected by re-hanging, lipping or frame adjustment, then re-measured.